Inverter
 |
|
 |
| |
|
|
|
KNOW HOW IT WORKS
? |
|
SWASTIK POWER INVERTERS / UPS
operates on Lead Acid
Batteries. When mains power fails SPI / SPU instantly draw power from
batteries and supplies to utilities. As soon as power is reinstated
SPI / SPU stops drawing power from batteries and starts recharging
them. All these actions take place automatically.
|
|
APPLICATION :
|
SWASTIK POWER INVERTERS / UPS can be used
at residence, Offices, Banks, Classes, Show rooms, Shops,
Hospitals, Laboratories, Hotels etc.
|
|
SALIENT FEATURES :
|
- Micro Controller
Controlled for Reliable operations & number of protections.
- Wide input
voltage range (150-280).
- CVCC PWM
Changer for smooth charging of batteries.
- Filtered
Output for Low Noise in fans and tubes.
- High Efficiency
by use of MOSFETs and CRGO laminations.
- Rugged design for Indian voltage
conditions.
|
|
|
TECHNICAL SPECIFICATIONS
:
|
|
MODELS |
SPI -250 |
SPI-350 |
SPI-500 |
SPI-750 |
SPI-1000 |
|
Rated power |
[at.p.f.0.8%] |
250W |
350W |
500W |
750W |
1KW |
|
Load |
Fans+Tubes |
2F+2T |
3F+3T |
4F+4T |
6F+6T |
8F+8T |
Battery
Voltage |
D.C. Volts |
12V |
12 |
12/24V |
24/36V |
24/36V |
Discharge
Current |
Amps |
20A |
30 |
40/20A |
30/20A |
40/30A |
Dimensions
(inches) |
W
D
H |
8
15
8 |
8
15
8 |
8
16.5
8 |
8
18
8 |
8
18
8 |
Weight
(Appr.) |
Kg. |
10 |
11 |
12 |
15 |
18 |
|
Input |
Voltage |
150-280 V |
|
Frequency |
50 H
± 5% |
|
Output |
Wave form |
Square & modified size wave
[quasi square wave] both available for different types of
appliances |
|
Frequency |
50 HZ
± 2% |
|
Voltage |
240 ± 8%
for square wave & 230 4% for quasi square wave |
|
Transfer
|
Mains to inverter |
< 140v. > 280 |
Both can be
varied. Mains on delay of 10 seconds. |
|
Inverter to mains |
> 150 v. < 265 |
|
Efficiency |
Approx. |
Approx.90 % |
|
Indication |
All visual (LEDs) |
Mains on, Inverter on,
Battery low, Overload, Charging on. |
|
Technology |
Inverter
charger |
Power MOSFETS push-pull with
PWM for squasi square wave
Two potential CVCC [ Constant Voltage Constant Current ] |
|
Protections |
Inverter |
Overload, Short Circuit,
Special Protection for Power MOSFET, against Inverter
output short with mains supply. |
|
Charger |
Current Limit & overcharge |
|
General |
Output (Fused), Battery
Reverse, Battery Undercharge. |
- Higher Power rated Inverters &
UPS available against order.
- Product specifications subject
to continuous technical improvements.
|
|
 |
| |
|
INDICATION |
CHECK UP |
|
MAINS PRESENT
BUT NO POWER AT OUTPUT |
| Green
LED of mains is off |
Check the input
switch on wall gang box, it must be on
position
|
| Green
LED of mains on |
Check
the output fuse on backside & ensure that output
plug is tight. |
|
MAINS FAIL BUT
NO POWER AT OUTPUT |
| Red
LED of the Inverter is off |
Check the position of ON/OFF LED on front panel. It
must be in ON position. |
| None
of LED glows |
Check the connection of the battery & the link wires
between two batteries. If they are corroded then clean
them with hot water & make sure of tight contact. |
|
Overload LED glows |
Reduce the load at output by switching off the switches
of appliances. Check whether SPI output is connected to
heavy load like Toaster, Hair Dryer, Refrigerator, Heater,
Iron etc. If found disconnect them. |
|
Battery low LED is on |
Press the reset switch. If battery low indicator is still on,
check the connection of battery & link wires between
two batteries. If they are corroded clean them with hot
water, be sure that nut-bolts are tight. |
|
MAIN PRESENT BUT CHARGING
INDICATOR OFF |
Yellow LED (Charging indicator) does not glow after
battery is used. |
Check the
connection of battery & link wires.
The Yellow LED (charging indicator) is off, if mains
voltage
is too low and battery is not being charged by
SPI... |
|
|
Request
a Quote
|
|
|